cover-life-export-58

TECHNICAL FEATURES I~ COVER life® CARACTERISTIQUES TECHNIQUES THERMAL CONDUCTIVITY CONDUCT/SIL/TE THERMIQUE Cover-Life sheets have avery low thermal conductivity·, equal to 0.225 Kcal/h.mK (see RP nr. 391G of the Laboratory CERISIE) due to their material composition. By comparison with other materials, Cover-Life has a thermal conductivity which is similar to concrete (K value=o.198), lower than asbestos board (K=o.232), 231 times lower than steel (K=52755), 1075 times lower than aluminium (K=242.858) and 1800 times lower than copper (K=405.538). 'Ability to insulate from and to transfer heat and cold. Grace aux matieres premieres utilisees a la production, la plaque Cover-Life a une conductibilite thermique· tres basse, equivalent a 0,225 Kcal/h/ml/'K certifie par le proces-verbal n· 391 G du laboratoire CER/5/E Pour simplifier la comparaison avec d'autres materiaux, retenons que la conductibilite thermique des produits Cover-Life est proche de celle du beton cellulaire (valeur K = 0,198), 4 fois inferieure a celle des produits en fibrociment (valeur K = 0,9961): 234 fois inferieure a celle de l'acier (valeur K = 52,755), 1079 fois inferieure a celle de /'aluminium !valeur K = 242,858) et 1800 fois inferieure a celle du cuivre !valeur K = 405,538). • capacite de transmission de la chaleur ou du froid. BARREL ROOFS AUTO CINTRABLE Apart from being flat, roofings can also have circular or cylindric shapes. Cover-Life sheets are adaptable to these designs according to certain bending limits. In the case of one single sheet installation, the bending radius of the Etruria model is equal to or greater than m5.00, and equal to or greater than m12 for the Romana model (see Installing Romana - Etruria - Greca). To verify if the roofing you require can be laid onto curved surfaces, use the formula below: Outre les toitures a versants plots, la couverture peut presenter differentes formes !circulaire, semi arrondie, etc.J. Les plaques Cover-Life repondent a cette exigence puisqu'elles sont semi f[exibles et peuvent dons certaines limites, etre cintrees : Les modeles Romana, Etruria et Greco peuvent etre courbes selon un rayon egal ou superieur a 5,00 m. Le modele Romana peut etre courbe selon un rayon egal ou superieur a 12, oo m TECHNICAL SUITABILITY AND WARRANTY CONFORM/TE TECHNIQUE Cover-Life multi-layer sheets are the result of industrial patents and innovative technologies. Thanks to great technical specializations, new materials and innovatory production processes, Cover-Life sheets meet high certification standards and have been classified into Category 1 ("A") in conformity with the application of two methods, CSE RF 1/75/Aand CSE RF 3/77, concerning the reaction to fire. According to the Method UNI 9177 the class of reaction to fire is 1. The dimensional stability of Cover-Life sheets remains unaltered even with considerable temperature variations because of their very low thermal expansion coefficient. The technopolymers used in Cover-Life sheets manufacturing provide outstanding thermal and acoustic insulation and a high resistance to accidental shocks. Furthermore, they withstand every kind of fume produced by chemical industries thanks to their elastomer lower layer. FIRST CORPORATION S.r.l. supplies Cover-Life sheets for residential, industrial and agricultural roofings and guarantees the best quality of their structure. Cover-Life sheets come with a15-year structural stability warranty from the date of manufacturing indicated on the product. The warranty does not cover damages due to improper transport, wrong installation of the sheets without suitable Cover-Life accessories or extraordinary events such as acts of vandalism, wars, earthquakes, natural disasters and sabotage. 124 Les plaques Cover-Life sont fabriquees selon une structure stratifiee issue des technologies industrielles brevetees. Grace a une maitrise technique de haut niveau et a /'utilisation de materiaux et de procedes innovants, les plaques Cover-Life repondent aux exigences les plus severes (Classe M1, ignifuges et auto-extinguibles). Meme soumises a des variations de temperatures importantes, elles conservent une stabilite dimensionnelle optimale grace a un coefficient de dilatation thermique extremement bas (0,042 mm par m/'C). Les technopolymeres utilises dons la fabrication des plaques Cover-Life offrent une capacite de transmission calorifique tres basse (elles peuvent done etre soumises aux chocs thermiques sans subir de dommages) et permettent d'absorber les nuisances sonores en cos de forte pluie ou de grele. Grace a une couche elastomere en finition inferieure, Les plaques Cover-Life offrent une excellente resistance a /'action corrosive des emanations de nature chimique : elles sont done insensibles a /'action des anhydrides sulfureux ou des brouillards so/ins, entre autres. La societe FIRST CORPORATION S.r.l., societe en charge de la commercialisation des produits Cover-Life pour la couverture des batiments a usage particulier, industriel et agricole, en assure done la qualite optimale. Les plaques Cover-Life sont garanties 15 ans sur le plan structure/ a partir de la date de fabrication inscrite sur le produit. La garantie exclut Les dommages causes par la manipulation, le transport et stockage des plaques. Sont egalement exclus Les dommages resultant de la mise en ceuvre non-conforme effectuee sans nos accessoires ainsi que tous dommages a caractere extraordinaire tels que vandalisme, guerres, tremblements de terre, catastrophes naturelles et sabotages, ou tout autre element exceptionnel.

RkJQdWJsaXNoZXIy MTIzMjc4Nw==