INSTALLING SHEETS LAYING DIRECTION To install the sheet Tegola you have to follow an obligatory laying direction from right to left and an optimum overlap designed to obtain the maximum usable roof area (see the picture on the right). The vertical overlap must be positioned preserving the aesthetic continuity of the sheets. INTERSECTION OF 4 SHEETS On the right you can see in details the intersection between vertical and horizontal overlapping of the sheets. To limit the thickening and keep good aesthetics on the intersection point of the four sheets, it is recommended to cut at 45· the left lower corner of sheet number 3 ( cut dimensions 8 x 8 cm). FLASHING Tegola flashings are put at the end of the sheets placed on the lateral edges of the roofing pitch to join them with the vertical wall and make the roofing continuous on each side. For a correct installation we suggest: • Lay the flashing on the lateral profile of the sheet and align it to its pitch (see picture 1) • Fix the flashing to the sheet on each wave with an Olandese washer ref. coooN (see picture 2/ A) • The flashing must also be fixed to the vertical wall using the universal o'ring caps (see picture 2/B) TEGOLA reinforced epais LAYING DIRECTION SENS DEPOSE INSTALLATION DIRECTIONDEPOSEDESPLAQUES La Plaque Tegola doit obligatoirement etre posee de droite i:t gauche et en respectant le recouvrement etudie pour obtenir la meilleure couverture possible (voir le schema a gauche). Le recouvrement vertical des plaques doit etre positionne en gardant la continuite esthetique de la couverture. INTERSECTION DE4 PLAQUES Agauche vous trouvez le detail de /'intersection entre recouvrement vertical et horizontal des plaques. Afin de limiter la surepaisseur et de conserver un bon esthetisme a /'intersection de 4 plaques, ii est conseille de couper a 45· /'angle inferieur a gauche de la plaque 3 (suivant Les dimensions 8 cm x 8 cm) comment indique dons le schema. RIVEARECOUVREMENT Les rives a recouvrement de la plaque Tegola permettent la finition entre Les plaques, la fartiere et la paroi verticale, afin d'assurer une continuite de la plaque de couverture en liaison avec Les parties laterales. Pour une bonne pose de l'accessoire en partant de la ligne d'egout: • Positionner la rive a recouvrement sur la premiere onde de la plaque Tegola et /'aligner au pas de la plaque (voir Fig. 1) • Fixer la rive a la plaque sur chaque onde avec le cavalier de fixation universe/ a joint COooN de la plaque Olandese (voir Fig. 2, detail A) • II est important egalement de fixer la rive sur la paroi verticale en utilisant Les cavaliers de fixation universels a joint (voir Fig. 2, detail B). ADVISABLE DISTANCE OVERLAP MINIMUM SLOPE SUGGESTIONS ON NUMBER AND POSITION OF THE FIXINGS ENTRAXE CONSEILLE RECOUVREMENT PENTEMINIMUM CONSEILS SUR NOMBRE ETPOSITION DES FIXATIONS 35
RkJQdWJsaXNoZXIy MTIzMjc4Nw==