rain-gutters-en-2024

INSTALLATION INSTRUCTIONS B C ROOF PROTRUSION: 1/3 of channel WIDTH RECOMMENDED BRACKET TO BRACKET DISTANCE: 50 cm FIRST BRACKET 30 cm FROM EDGE MAX cm. 5 0 cm. 30 MINIMUM DIFFERENCE IN HEIGHT: 1 cm EVERY 3 metres (0.33%) BEND THE BRACKET FOLLOWING ROOF SLOPE For optimum rainwater drainage, consider that the roof protrusion (tiles, roofing sheets, etc.) should cover 1/3 of the gutter channel width. The leaf strainer PF26, adjustable for diameters from 75 to 125 mm, is perfect to prevent wind-borne leaves or fibres f rom blocking downpipes. Brackets and rafters are ready for installation of a safety wire. 1) In some types of buildings, thanks to the characteristics of the façade or reduced roof pitch protrusion, the gutter channel can be installed using directly the PVC brackets. These accessories are available for most gutter types. 2) In this case, installation is very simple. Just follow installation instructions detailed above and secure the PVC brackets to the façade. 3) Mount the gutter channel by inserting it under the PVC bracket inner seat (B), and then slightly turn it to drive the curl rim into the PVC bracket outer seat (C) to lock the gutter. ASSEMBLING THE PVC BRACKETS 18 PROTRUSION

RkJQdWJsaXNoZXIy MTIzMjc4Nw==